Chilled Water Based In-row Front Cooler Unit

Canovate Electronics’ In-Row, chilled-water based front coolers were designed to work specifically in cold and hot aisle containment applications in dense data center environments, without the need for a raised floor. Their modular engineering gives you the ability to meet the most demanding data center needs, while also precisely controlling your capital expenditure. You can invest in the amount of cooling you need now and, as your needs grow, add more units to your system for increased cooling.

Canovate has designed a number of chilled-water front coolers to meet a variety of needs in data center environments. They range in size from 300-600mm wide and 1000-1200mm deep, and are 2000mm tall. Depending on the model, they can achieve cooling capacities of up to 30 or 60kW.

Because chilled-water based systems are part of a chiller system, they don’t rely on condensers to cool their refrigerant. Instead, water chilled to 14°C is brought through a closed loop to the air handling unit’s cooling fans.

Description

Through heavy investment in R&D, Canovate has developed a practical design with greater efficiency than other In-Row, chilled water based front coolers. Our variable-speed fans are temperature controlled to automatically deliver the right amount of cooling and adjust for spikes and gaps in server usage. Their motors are a brushless (electronically commutated) design for increased power, speed, control, and reliability, and reduced maintenance.

Our design is further improved to ease the cycles of maintenance and repair, by making our cooling fans hot swappable. Should a problem occur and a fan need replaced or repaired, operations can continue without impacting operations or customer experience.

The system can be monitored and controlled with an optional SNMP (Simple Network Management Protocol) card. This allows administrators to monitor how well the system is working holistically, and to better identify any possible hotspots, leaks in the hot/cold aisle containment, under-used servers, or other issues.

Highlights:

*  Specially developed for cold & hot aisle containment applications

*  Modular construction

*  In-Row technology

*  No raised floor required

*  Variable speed fans

*  Modular design allows for capacity expansion

*  30kW or 60kW cooling capacity

*  Temperature-controlled, hot-swappable fans

*  EC-Technology

*  No condenser needed due to 14°C inlet water temperature

*  Increased free cooling capacity enabled by high inlet water temperature (14°C)

*  Remotely control and monitor coolers with optional SNMP card

Technical Document

Technical Document | Installation Guide | Operation Manuel | Catalog

Technical Spesification

Specifications 30 kW Front Cooler 60 kW Front Cooler
Cooling capacity 30 kW 60 kW
Air inlet 38 °C 38 °C
Number of fans 3 x 3 x
Type of fans Radial Axial
Air flow 3.800 m³/h 9.600 m³/h
Power consumption 980 Watt 1250 Watt
Current 4.3 A 5.8 A
Power supply 230 Volt 50/60 Hz. 230 Volt 50/60 Hz.
Water temperature inlet +14 °C +14 °C
Water temperature outlet +20 °C +20 °C
Water flow 4,8 m³/h 7,11 m³/h
Pressure drop 42 kPa 33 kPa
Water connection 1 1/4 inch. 1 1/2 inch.
Number of airfilter 1 x 3 x
Type of airfilter G 2 G 2
Noise level in 1 mtr. distance 62 dB(A) 72 dB(A)
Dimensions
Width 300 mm 600 mm
Depth 1.000/1.200 mm 1.000/1.200 mm
Height 2.000 mm 2.000 mm
Weight 200 kg. 252 kg.
Color RAL 9005 / RAL 7035 RAL 9005 / RAL 7035
Product Code Description (230VAC 50Hz/60Hz)
DC-FCWX-4230-E01EU1-R0 CW Front Cooler 30kW 42U 300 x 1000
DC-FCWX-4232-E01EU1-R0 CW Front Cooler 30kW 42U 300 x 1200
DC-FCWX-4260-F01EU1-R0 CW Front Cooler 60kW 42U 600 x 1000
DC-FCWX-4262-F01EU1-R0 CW Front Cooler 60kW 42U 600 x 1200
DC-FCWX-4730-E01EU1-R0 CW Front Cooler 30kW 47U 300 x 1000
DC-FCWX-4732-E01EU1-R0 CW Front Cooler 30kW 47U 300 x 1200
DC-FCWX-4760-F01EU1-R0 CW Front Cooler 60kW 47U 600 x 1000
DC-FCWX-4762-F01EU1-R0 CW Front Cooler 60kW 47U 600 x 1200

Price Quote