• Linkedin
  • Twitter
  • Youtube
  • Instagram
  • Facebook
  • NEWS
  • LIBRARY
  • CONFIGURATOR
  • English
  • Español
  • Français
+90 (216) 484 22 22
info@canovate.com
Canovate
  • HOME
  • ABOUT
    • About Canovate Electronics
    • Canovate Group Companies
    • Milestones
    • Mission, Vision, Values
    • Portrait
    • Management Team
    • News
    • Press
    • Library
  • PRODUCTS & SOLUTIONS
    • Data Centers
      • Data Center Solutions
      • Data Center Products
    • Fiber Optic Infrastructure
      • Optical Distribution Frame Solutions
      • High Density Smart ODF
      • Fiber Tree System
      • Fiber Tree Solutions
      • GPON Splitter Modules
      • Fiber Patchpanels
      • MTP&MPO Modules
      • Fiber Duct Solutions
      • Outdoor Fiber Cabinet Solutions
      • Splice Closures
      • Last Mile Solutions
      • Fiber Accessories
    • Structural Cabling
      • Copper Solutions
      • Fiber Solutions
    • Racks & Cabinets
      • Floor Standing Rack Cabinets
      • Wallmount Solutions
      • Accessories
      • Power Distribution Unit Solutions
      • Outdoor Solutions
  • CAREER
  • CONTACT
  • Search
Home / Products & Solutions

Perforated Curved Door for Aluminium Cabinets

Perforated Curved Door (Inorax-AL)

15/01/2019/in Single Door /by Betül Ceylan
Back
Perforated Curved Door for Aluminium Cabinets Perforated Curved Door for Aluminium Cabinets
Perforated Curved Door for Aluminium Cabinets Perforation Details of Perforated Curved Door
Data Sheet Catalog
Video

Perforated Curved Door Options


Material 1.2 mm Steel Finish Electrostatic Powder Paint
Perforation Rate %67 Color RAL 7035 and RAL 9005
H (U) W (mm) D (mm) H (mm) Weight kg Part No
26U 600 57 1264 9,41 CPZ-X-266Y0-0905
36U 600 57 1709 12,55 CPZ-X-366Y0-0905
39U 800 76 1842 17 CPZ-X-398Y0-0905
42U 600 57 1975 14,43 CPZ-X-426Y0-0905
42U 800 76 1975 18,18 CPZ-X-428Y0-0905
47U 600 57 2198 16,00 CPZ-X-476Y0-0905
47U 800 76 2198 20,16 CPZ-X-478Y0-0905

https://canovate.com/wp/wp-content/uploads/2017/10/Perforated-Curved-Door-Options_01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-15 17:39:032019-03-05 13:17:19Perforated Curved Door (Inorax-AL)
19 Cantilever Shelf-01

19″ Cantilever Shelf

08/01/2019/in Shelves /by Betül Ceylan
Back
19 Cantilever Shelf-01
19 Cantilever Shelf-01 19 Cantilever Shelf-02
Data Sheet Catalog
Video

Technical Details

H (U) D (mm) W (mm) Inner W (mm) Weight (kg) Part No
1U 150 483 437 0,84 CCA-X-1001
2U 250 483 437 1,58 CCA-X-1002
2U 400 483 437 2,43 CCA-X-1003
Material 1.5 mm Steel
Maximum Static Load 15-25 kg
Finish Electrostatic Powder Paint
Packaging One piece in a box
https://canovate.com/wp/wp-content/uploads/2017/05/19-Cantilever-Shelf-01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-08 10:51:382019-03-05 15:54:2919" Cantilever Shelf
Cold & Hot Aisle Containment-01

Cold & Hot Aisle Containment

03/01/2019/in Maxi Data Center Solutions /by Betül Ceylan
Back
Cold & Hot Aisle Containment-01 Cold & Hot Aisle Containment-01
Cold & Hot Aisle Containment-01 Cold & Hot Aisle Containment-02 Cold & Hot Aisle Containment - Top Cover Cold & Hot Aisle Containment-Skirt Type Blanking Panel Cold & Hot Aisle Containment System 01 Cold & Hot Aisle Containment System 02 Cold & Hot Aisle Containment System 03
Data Sheet Installation Manual Catalog
Video

Cold & Hot Aisle Containment is highly modular, scalable, expandable and retrofitable system. It enables isolation of hot and cold aisles to maximize cooling system efficiency and minimize cooling energy requirement. It provides efficient energy management and energy savings increase to 50%. The top cover of the Cold & Hot Aisle Containment is made from easily tempered glass panel to maximize the available light and reduce the fire risk.  Ths skirt type blanking panels closes the gap between 19” mounting rails and side panels and enables zero U patch panel fitting and cable management. Also Cold & Hot Aisle Containment System must be built on raised floor to maximize cold air intake efficiency.

  • Optimum cooling solution for big and medium scale Data Centers coupled with CRAC units to increase efficiency of cooling system
  • Provides moderate efficiency, energy saving and free cooling capabilities
  • Increase server performance and cooling efficiency in Data Centers
  • The existence of cold & hot aisle containment eliminates the existence of hot spots
  • Modular Concept
  • Retrofitable
  • Cooling capacity of up to 10kW per rack
  • Green IT
  • Complete system solution:
    – Power management
    – Monitoring
    – Cooling
    – Security
  • Return on investment within 30 months

Accessories



Cold & Hot Aisle Containment-Raised_Floor


Raised Floor

Cold & Hot Aisle Containment -Brush

Dust protection

Cold & Hot Aisle Containment - Swing_Doors

Swing Doors

Cold & Hot Aisle Containment - Sliding Doors

Sliding Doors

Cold & Hot Aisle Containment -Blanking Panels

Blanking Panels

Cold & Hot Aisle Containment System must be built on raised floor to maximize cold air intake efficiency. Manual or electronic locking Sliding Door systems for access management.

Aisle_Entrance_Door_Top_Cover

The Parts of Cold & Hot Aisle Containment System

1. Aisle Entrance Door

Sliding Door Manual System

Product Code Product Description
DC-D1-X-42220 1200 mm width, For 42U Cabinets
DC-D1-X-47220 1200 mm width, For 47U Cabinets

Sliding Door Automatic System

Product Code Product Description
DC-D4-X-42220 For 42U Cabinets, 1200 mm width (Button)
DC-D4-X-47220 For 47U Cabinets, 1200 mm width (Button)
DC-D4-X-42220-P For 42U Cabinets, 1200 mm width (Fingerprint Reader)
DC-D4-X-47220-P For 47U Cabinets, 1200 mm width (Fingerprint Reader)
DC-D4-X-42220-K For 42U Cabinets, 1200 mm width (Key Pad)
DC-D4-X-47220-K For 47U Cabinets, 1200 mm width (Key Pad)
DC-D4-X-42220-C For 42U Cabinets, 1200 mm width (Card Reader)
DC-D4-X-47220-C For 47U Cabinets, 1200 mm width (Card Reader)

Swing Door Manual System
1 piece Left Door Panel, 1 piece Right Door Panel

Product Code Product Description
DC-D3-X-422Y0 For 42U Cabinets, 1200 mm width
DC-D3-X-472Y0 For 47U Cabinets, 1200 mm width

2. Top Cover

Product Code Product Description
DC-T-X-YY3Y0 For 300 mm width cooler, 1200 mm depth
DC-T-X-YY6Y0 For 600 mm width cabinet, 1200 mm depth
DC-T-X-YY8Y0 For 800 mm width cabinet, 1200 mm depth

The Accessories of Cold & Hot Aisle Containment System

Skirt Type Blanking Panel
2 pcs Blanking Panel between 19” mounting rail and cabinet profile

Product Code Product Description
DC-B3-X-428Y0 For 42u 800 width cabinet
DC-B3-X-478Y0 For 47u 800 width cabinet
DC-B3-X-426Y0 For 42u 600 width cabinet
DC-B3-X-476Y0 For 47u 600 width cabinet

Baying Kit 4 pieces in a set

Product Code Product Description
DC-B5-X-YYYY00 Front&rear Baying kit

Plinth

H (mm) W (mm) D (mm) Part No
60 300 1000 DC-B6-X-YY300
60 300 1200 DC-B6-X-YY320
60 600 1000 DC-B6-X-YY600
60 600 1200 DC-B6-X-YY620
60 800 1000 DC-B6-X-YY800
60 800 1200 DC-B6-X-YY820
https://canovate.com/wp/wp-content/uploads/2017/10/Cold-Hot-Aisle-Containment-01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 10:53:552019-03-05 10:24:42Cold & Hot Aisle Containment
Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based

Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based

03/01/2019/in Mini Data Center Solutions /by Betül Ceylan
Back
Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based
Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based Mini Data Center
Data Sheet Catalog Video

Highlights of Mini Data Center Server Rack with Integrated Side Cooler 

  • Integrated monitoring system
  • Install mini Data Center where you want and need it
  • Rapid deployment in 4-6 weeks from plan to start-up
  • Low total cost of ownership
  • Up to 50% less space required
  • No raised floor required
  • Full turnkey Data Center including cooling, structured cabling, monitoring,
  • Power management and protection
  • Scalable from 1 rack to hundreds of racks
  • Standalone Data Center
  • Individual rack cooling up to 30 kW
  • High level security within rack fire protection and monitoring systems
  • Advanced power management with IP PDU and UPS systems
  • Internal redundancy achieved by using 3x fans.
  • External redundancy achieved by using N+1 side coolers
  • Structured cabling solutions with overhead cable channels
  • Access Control options with either keypad, RFID card reader or fingerprint reader to open the cabinet doors

Applications

  • High density servers exceeding 10 kW
  • Mobile Containers/Shelters
  • Branch Offices
  • Disaster recovery operations
  • Small clinics/hospitals
  • Warehouses
  • Remote installations
  • Temporary installation
  • Mobile applications
Air cooled(DX) SideCooler Water Based Side Cooler
Cooling Capacity 28 kW 30 kW
Rack Height 42U/47U 42U/47U

Components of the Mini Data Center


mini_data_center_03

Mini Data Center Configuration
A Reference Side Cooler Application Layout



A Snapshot from Side Cooler Control & Monitoring System


https://canovate.com/wp/wp-content/uploads/2017/10/mini_data_center_04.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 11:01:572019-09-04 16:11:03Mini Data Center Server Rack with Integrated Side Cooler DX or Water Based

Micro Data Center

06/05/2020/in Micro Data Center Solutions /by Betül Ceylan
Back
Micro Data Center solutions- components Micro Data Center Components
Micro Data Center solutions- components Micro DC - graphic cost reduction
Data Sheet Technical Manual Catalog Video

An emerging trend in data center design is modular Micro Data Center, which provides cost effective, energy efficient data center service with a rapid deployment time frame.

Canovate® Micro Data Center solution is the right and cost effective answer for this increasing demand. Canovate® Micro DC solution is an integrated data center solution that incorporates Racks, UPS , Cooling , Fire Suppression, PDU and Environmental Monitoring System (EMS) in a compact single platform. Remote monitoring feature allows the group headquarters to perform unified management and allows equipment rooms in branches to operate properly even when left unattended.

The Micro Data Center approach also reduces CAPEX dramatically in comparison with traditional brick and mortar DC construction and it will enable your current and future customers to access the cloud easily and benefit from a resilient and fully supported infrastructure.

Benefits of Canovate Micro Data Center

Accelerated Deployment: Deploy turnkey rack-level infrastructure in max 1 hour time.
Lower CAPEX: Significantly lower initial investment and construction cost compared to classical Data Centers.
Increased Energy Efficiency: Dramatically lower your cooling and power OPEX costs
Customizable: Can be customized easily according to your cooling and power requirements.
Significant Energy Savings: You don’t need to cool the entire IT room, just cool the Micro DC. Green IT.
Modular: Additional Micro DC units can be added according to the growth of your IT requirements. Pay-As-You-Grow!
Portable: Micro DC can be installed on wheels making it easy for it to be moved to different locations.
Security: Keeps mission critical data in a secure environment, increases data and hardware protection and guarantees 24/7 business continuity via integrated fire suppression and EMS systems
Facility Maintenance: The ability to minimize IT infrastructure maintenance to lower overall Data Center maintenance labor costs.
Limited Operation Risk: The complete system is coming as factory tested and ready to install. Plug and Play.
Standardization: Same standard solution in all your branch offices limits risks of human failure and lowers operating & maintenance costs.
No need for skilled IT personnel : You don’t need to maintain IT personal in every location , hundreds of Micro DC’s can be controlled remotely from your Head Quarters.
Affordable by Small Businesses: You don’t need to worry for a complex DC design and installation work.

Applications
• Small and Medium Size Enterprises (SME’s)
• Branch offices of financial institutions (Banks, Insurance companies)
• Instant data center
• Branch offices of government institutions and utilities (Police, Army, Schools, Electricity, Water companies etc)
• Companies who wants to connect the cloud instead of investing in a big data center
• Exchange offices & Hubs of Telco’s and GSM companies
• Remote locations where there is no dedicated IT personnelavailable
• Manufacturing companies for automation control and IT services
• Disaster recovery

Server Room Construction Micro Data Center
Initial Costs High Low
Construction Time Long Short
Flexibility Low High
Cooling Efficiency Low High
Scalability Low High

Highlights

• Micro Plug & Play Data Center including cooling, fire suppression, monitoring, power management and protection
• Stand-alone Data Center
• Eliminates raised floor and external cooling equipment requirements
• Individual rack cooling with from 2 kW up to 4 kW
• High level security with in rack fire protection and monitoring systems
• Advanced power management enabled by IP PDU and UPS systems
• Install Data Center where you want and need it
• Rapid deployment in 4-6 weeks from plan to start-up
• Low total cost of ownership
• Up to 50% space savings
• EMS (Environmental Monitoring System)
• DCIM option
• IP PDU
• UPS
• Fire Detection/Extinguisher System (2U)
• Protection Grade:IP54

Order Information

Height U Outer Width (W) mm Outer Depth (D) mm Outer Height (H) mm (Including Cooling unit) 19” Rails Adjustable Depth Range (c) Cooling Capacity Part No
24U 600 1000 1651 129-729 2 kW CPJ-X-2460A-T2K
24U 600 1000 1651 129-729 4 kW CPJ-X-2460A-T4K
36U 600 1000 2263 129-729 2 kW CPJ-X-3660A-T2K
36U 600 1000 2263 129-729 4 kW CPJ-X-3660A-T4K
42U 600 1000 2529 129-729 4 kW CPJ-X-4260A-T4K

Outer Heights include cooling unit
Height of Cooling Unit: 2 kW : 496 mm, 4 kW : 496 mm

* X : Color code = 7: RAL 7035 (Grey); 9: RAL 9005 (Black)

https://canovate.com/wp/wp-content/uploads/2019/01/Centre-de-Données-Micro.jpg 1000 1000 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2020-05-06 13:45:012020-10-26 09:17:34Micro Data Center
Can-Breeze Mikro Veri Merkezi Çözümleri

CAN-BREEZE Micro Data Center

03/01/2019/in Micro Data Center Solutions /by Betül Ceylan
Back
Micro-Data-Center_03
Micro-Data-Center_03
Data Sheet Quick Installation Guide Operational Manual Catalog
Video

CAN-BREEZE in rack cooling system is a direct-cooled server cabinet consisting from a lateral cooling device as an indoor unit and an AC outdoor unit. The cooling system provides energy-efficient cooling by latest inverter technology. The cooling capacity and so that the power consumption adapt to the actual costs incurred heat load.

The Side Cooling Rack has close loop system, thus, there is no air leakage between internal air and room air. The noise level is due to the extremely quiet internal side cooling unit is very low and is only about 49 dB(A). These values are below the usual noise in offices. The preparation and installation of the product is very simple.

The outdoor unit can be mounted to a facade wall, placed on a flat roof or on the ground. The Side Cooling Rack’s cooling capacity is available in range between 3,2kW and 14 kW. The internal side cooling unit blows cold air into the front of the 19” mounted devices and collects the hot air from back. Blank (unused) units should be closed with 19 “ blanking panels in order to prevent the cold air short-circuit. The internal side cooling unit has a condensate water pan. Condensed water is collected in the pan, and drained away by drainage hose (customer supplied).

Technical Features

Material Frame; Anodized aluminum extrusion profiles. Other parts : 1,2 and 2 mm steel
Color RAL 7035 or RAL 9005
Compliance RoHS, UL Certified
Maximum Static Load Up to 2000 kg.
Finish Doors, side panels, top and bottom covers: Electrostatic Powder Paint
19” mounting rails: Zinc-plated
Related Accessories Cable Organizer, Blanking Panels, Cable Channels

Standard Configuration

• Extruded Aluminum frame chassis up to 2000 kg
• IP Protection : IP54
• Tempered glass front door with swing handle multi-point lock
• Solid rear door with swing handle multi-point lock
• Special polyurethane gasketing on doors and panels to ensure IP protection
• Deflectors to guide cold air from the AC unit to the front of the rack
• Solid removable side panels
• Bottom sheet with adjustable IP protected cable entry
• 2 pairs of depth adjustable heavy duty 19” mounting rails
• 2 pairs of adjustable feet
• Color RAL7035 or RAL 9005
• RoHS compliant, UL certified

Order Information

Height U Outer Width (W) mm Outer Depth (D) mm Outer Height (H) mm (Including Cooling unit) 19” Rails Adjustable Depth Range (c) Weight kg Cooling Capacity Part No
36U 800 1000 1767 129-829 151,5 8kW CPJ-X-3680A-I8
36U 800 1200 1767 129-1029 165,5 8 kW CPJ-X-3682A-I8
42U 800 1000 2033 129-829 166,3 8 kW CPJ-X-4280A-I8
42U 800 1200 2033 129-1029 180,4 14 kW CPJ-X-4282A-I14
47U 800 1000 2255 129-829 181,7 8 kW CPJ-X-4780A-I8
47U 800 1200 2255 129-1029 196,3 14 kW CPJ-X-4782A-I14

CAN-BREEZE Data Center Configurations

CAN-BREEZE-I


1 Cooling Unit / 1 Rack

CAN-BREEZE-II


2 Cooling Units / 1 Rack (Reduction Application)

CAN-BREEZE-III


1 Cooling Unit / 2 Racks (Shared Application)

CAN-BREEZE-IV


2 Cooling Units / 2 Racks (Redundant or Shared Application)

https://canovate.com/wp/wp-content/uploads/2018/03/can_breeze_micro_veri_merkezi-01.jpg 1000 1000 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 11:48:032019-03-05 10:56:30CAN-BREEZE Micro Data Center
RC4-Anti Theft Micro Data Center_01

RC4-Anti Theft Micro Data Center

03/01/2019/in Micro Data Center Solutions /by Betül Ceylan
Back
RC4-Anti Theft Micro Data Center_01
RC4-Anti Theft Micro Data Center_01 RC4-Anti Theft Micro Data Center_02
Data Sheet Catalog
Video

3kW Cooling, Electronic Access, UPS, Intelligent Patch Panel, Environmental Monitoring
Canovate® RC4- Cabinet is the perfect solution to protect your mission critical equipment from any unauthorized access (theft protection) and vandalism attempt.

RC4 Norm: The experienced thief/intruder should not enter the cabinet for 10 minutes by using saw, axe, accu-drilling machine, hammer and chisel. (DIN V ENV 1630, 1999-04)

Technical Features

  • H x W x D: 42U x 900mm x 1100mm
  • IP54, RC4 certified
  • 3 kW Cooling capacity with heat exchanger
  • Steel frame chassis according to 25mm DIN system
  • Double skin front door and side & rear panels
    – Outer skin: 1.5 galvanized steel
    – Inner skin: 0.8 mm special undrillable/armored steel
    – Impact resistant grill structure between inner and outer skin
  • Specially designed 5-point WK4 locking mechanism
  • 1200 kg carrying capacity
  • Depth adjustable 19” mounting rails with U markings
  • Electronic lock with keypad, integrated to monitoring System
  • Shielded cable channels for data and power cabling
  • Side panels, top and bottom sheets are bolted internally
  • Adjustable feet
  • Earthing kit and earthing bar
  • RAL 7035 powder coated

https://canovate.com/wp/wp-content/uploads/2017/10/RC4-Anti-Theft-Micro-Data-Center_01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 13:09:582019-03-05 10:59:47RC4-Anti Theft Micro Data Center
Mobile Data Center Solutions_01

Mobile Container

03/01/2019/in Mobile Data Center Solutions /by Betül Ceylan
Back
Mobile Container _02 Mobile Container
Mobile Container _02 Mobile Container _04 Mobile Container _03 Mobile Data Center Solutions_01
Data Sheet Catalog Video

The mobile container provides a protected housing for the server cabinets, power distribution system, cooling system, monitoring system, fire control system, and lighting system. The container performs the following functions:

  • Houses the container components which can be interconnected inside in a centralized and manner.
  • Provides a protected environment to protect the container from external impact.

Technical Specifications of Mobile Container 

1. Container / Shelter size : 12192 mm x 2438mm x 2896mm
(high cube : 40 ft)
2. Outer / Inner sheet : Pre-painted Galvanized GI Sheet
3. Sheet Thickness : 0.6mm
4. Rockwool insulation thickness : 50mm overall
5. Floor Panel : 100 mm thickness (19mm plywood with 80 mm
rockwool insulation and 0.6 mm sheet thickness)
6. Primary roof
7. 1 mtr extended ISMB / ISMC
8. Cable Tray
9. Door lock system


Internal Layout of Container


Mobile_Container_layout

Other Mobile Data Center Configurations

Other Mobile Data Center Configurations_01 Other Mobile Data Center Configurations_02 Other Mobile Data Center Configurations_03

https://canovate.com/wp/wp-content/uploads/2017/10/Mobile-Data-Center-Solutions_01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 13:22:422019-03-05 11:03:09Mobile Container
Chilled Water Based Cooling_01

Side Cooler: Chilled Water Based Cooling

03/01/2019/in Side Cooler /by hakan
Back
Chilled Water Based Cooling_01 Chilled Water Based Side Cooler
Chilled Water Based Cooling_01 Chilled Water Based Cooling_02 Chilled Water Based Cooling_03 Chilled Water Based Cooling_04 Chilled Water Based Cooling_05
Data Sheet Catalog
Video

Highlights

  • Chilled water based cooling
  • No raised floor required
  • 30 kW cooling capacity
  • Efficient power consumption
  • Easy adaptation to different racks
  • Mountable to the side of the rack
  • Easy installation on the existing racks
  • Patented space saving shape
  • Integrated monitoring system
  • Hot-swappable fans
  • 300 mm width
  • No condensing water due to 14°C inlet water temperature
  • More than 1000 installations worldwide

Specifications
Cooling capacity 30 kW
Air inlet 38 °C
Number of fans 3 x
Type of fans Radial
Air flow 3.800 m³/h
Power consumption 980 Watt
Current 4.3 A
Power supply 230 Volt 50 Hz.
Water temperature inlet +14 °C
Water temperature outlet +20 °C
Water flow 4,8 m³/h
Pressure drop 42 kPa
Water connection 1 1/4 inch.
Noise level in 1 mtr. distance 62 dB(A)
Dimensions
Width 300 mm
Depth 1.000 mm
Height 2.000 mm
Weight 205 kg.
Color RAL 9005 / RAL 7035
Product Code Description (230VAC 50Hz/60Hz)
DC-SCWX-4230-E01EU1-R0 CW Side Cooler 30kW 42U 300×1000
DC-SCWX-4232-E01EU1-R0 CW Side Cooler 30kW 42U 300×1200
DC-SCWX-4730-E01EU1-R0 CW Side Cooler 30kW 47U 300×1000
DC-SCWX-4732-E01EU1-R0 CW Side Cooler 30kW 47U 300×1200
https://canovate.com/wp/wp-content/uploads/2017/10/Chilled-Water-Based-Cooling_01.jpg 500 500 hakan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png hakan2019-01-03 15:42:092019-03-05 10:37:05Side Cooler: Chilled Water Based Cooling
Cool-FCW Chilled Water Based Coolin_01

Front Cooler: Chilled Water Based Cooling

03/01/2019/in In-Row Cooler (Front Cooler) /by Betül Ceylan
Back
Cool-FCW Chilled Water Based Coolin_01
Cool-FCW Chilled Water Based Coolin_01 Cool-FCW Chilled Water Based Coolin_02
Data Sheet Quick Installation Guide Operational Manual Catalog
Video

Highlights

• Specially developed for cold & hot aisle containment applications
• Modular construction
• In-Row Technology
• No raised floor required
• Variable speed fans
• Modular design: Allows capacity expansion
• 30 kW or 60 kW cooling capacity
• Temperature controlled fans
• Hot-swappable fans
• EC-Technology
• No condenser needed due to 14°C inlet water temperature
• Increased free cooling capacity enabled by high inlet water temperature 14°C
• Remotely control and monitor coolers with optional SNMP card.

Specifications 30 kW Front Cooler 60 kW Front Cooler
Cooling capacity 30 kW 60 kW
Air inlet 38 °C 38 °C
Number of fans 3 x 3 x
Type of fans Radial Axial
Air flow 3.800 m³/h 9.600 m³/h
Power consumption 980 Watt 1250 Watt
Current 4.3 A 5.8 A
Power supply 230 Volt 50/60 Hz. 230 Volt 50/60 Hz.
Water temperature inlet +14 °C +14 °C
Water temperature outlet +20 °C +20 °C
Water flow 4,8 m³/h 7,11 m³/h
Pressure drop 42 kPa 33 kPa
Water connection 1 1/4 inch. 1 1/2 inch.
Number of airfilter 1 x 3 x
Type of airfilter G 2 G 2
Noise level in 1 mtr. distance 62 dB(A) 72 dB(A)
Dimensions
Width 300 mm 600 mm
Depth 1.000/1.200 mm 1.000/1.200 mm
Height 2.000 mm 2.000 mm
Weight 200 kg. 252 kg.
Color RAL 9005 / RAL 7035 RAL 9005 / RAL 7035
Product Code Description (230VAC 50Hz/60Hz)
DC-FCWX-4230-E01EU1-R0 CW Front Cooler 30kW 42U 300 x 1000
DC-FCWX-4232-E01EU1-R0 CW Front Cooler 30kW 42U 300 x 1200
DC-FCWX-4260-F01EU1-R0 CW Front Cooler 60kW 42U 600 x 1000
DC-FCWX-4262-F01EU1-R0 CW Front Cooler 60kW 42U 600 x 1200
DC-FCWX-4730-E01EU1-R0 CW Front Cooler 30kW 47U 300 x 1000
DC-FCWX-4732-E01EU1-R0 CW Front Cooler 30kW 47U 300 x 1200
DC-FCWX-4760-F01EU1-R0 CW Front Cooler 60kW 47U 600 x 1000
DC-FCWX-4762-F01EU1-R0 CW Front Cooler 60kW 47U 600 x 1200

https://canovate.com/wp/wp-content/uploads/2017/10/Cool-FCW-Chilled-Water-Based-Coolin_01.jpg 500 500 Betül Ceylan https://canovate.com/wp/wp-content/uploads/2017/03/logo-web.png Betül Ceylan2019-01-03 14:42:372019-03-05 10:27:45Front Cooler: Chilled Water Based Cooling